Table 54: Basic parameters G2.1
Index Parameter Min Max Unit Default Cust ID Description
P2.1.9 *
Nominal current
of the motor
Varies Varies A 5.40 113
Find the value In
on the rating plate
of the motor.
P2.1.10 Motor cos phi 0.30 1.00 0.85 120
Find the value on
the rating plate of
the motor.
P2.1.11 I/O reference 0 15/16 0 117
0 = AI1
1 = AI2
2 = AI1+AI2
3 = AI1-AI2
4 = AI2-AI1
5 = AI1xAI2
6 = AI1 Joystick
7 = AI2 Joystick
8 = Keypad
9 = Fieldbus
10 = Motor poten-
tiometer
11 = AI1, AI2 mini-
mum
12 = AI1, AI2 maxi-
mum
13 = Max fre-
quency
14 = AI1/AI2 selec-
tion
15 = Encoder 1
16 = Encoder 2
(NXP only)
P2.1.12
Keypad control
reference
0 9 8 121
Select the fre-
quency reference
input when the
control place is
Panel.
0 = AI1
1 = AI2
2 = AI1+AI2
3 = AI1-AI2
4 = AI2-AI1
5 = AI1xAI2
6 = AI1 Joystick
7 = AI2 Joystick
8 = Keypad
9 = Fieldbus
P2.1.13
Fieldbus control
reference
0 9 9 122
See P2.1.12
MULTI-PURPOSE CONTROL APPLICATION VACON · 143
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM
6

Table of Contents

Other manuals for Vacon NX series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX series and is the answer not in the manual?

Vacon NX series Specifications

General IconGeneral
Product typeAC Drive
Output voltage range0-Uin
Frequency range0-500 Hz
Enclosure classesIP00, IP21
Mounting typesWall
Braking chopperIntegrated or external
EMC filterBuilt-in or external
Control modesScalar, Vector
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Communication optionsModbus, Profibus, CANopen, Ethernet
Ambient temperature range-10°C to +50°C
Cooling methodAir-cooled