Communication description
Register number 1 (1-based Modbus register number) = 0000
hex
 (0-based register
address used in actual communication) based on the Modbus
reference in HMP Series with MMP8 and TMP1 User Guide
(M212022EN)
Data format Two 16-bit Modbus registers interpreted as IEEE 754 binary32
floating point value, least significant word first
Returned value 41F47AE1
hex
, which is binary32 representation of 30.56 (%RH)
Indigo510, Indigo520 User Guide M212287EN-N