Installation Manual _________________________________________________________________
98 __________________________________________________________________ M210485EN-B
WARNING
To protect personnel and the wind sensor, a lightning rod must be
installed with the tip several feet above the wind sensor. The rod
must be properly grounded, compliant with all applicable safety
regulations.
13. Attach the cables to the mast with the cable ties.
14. Connect the signal cable to the correct connector on the logger
tube, see section Connecting Sensors to the Logger Tube on
page 108.
15. Connect the DC power cable to the correct connector on
QMP202MP, see section Connecting Sensors to QMP202MP on
page 107.
0306-043
Figure 83 Ultrasonic Wind Sensor Mounted to the Mast
The following numbers refer to Figure 83 above:
1=Cables
2 = Opening for the cables
3 = Mounting clamp
4 = Ultrasonic wind sensor
5 = Securing screw