Installation Manual _________________________________________________________________
108 _________________________________________________________________ M210485EN-B
Connecting Sensors to the Logger
Tube
The sensors and the applicable cables that are connected to the upper
plate of the logger tube are listed in Table 5 below.
Table 5 Sensors, Cables, and the Connectors on QME101M
Sensor Cable Connector on Logger Tube
Rain Gauge QMR101M Connected to
sensor
Rain, blue connector on the
upper base
Air Temperature and
Relative Humidity
SensorQMH101M
Connected to
sensor
Temp/Humidity, red
connector on the upper base
Ultrasonic Wind Sensor
WS425
ZZ212024 Wind, white connector on
the upper base
Connecting Logger Tube to
QMP202MP
Three cables should be connected between the logger tube and
QMP202MP as follows:
1. Connect the input data cable (ZZ45123) between the connector
Enhancement that is marked with a green arrow at the lower
base and the connector Conn. to MAWS on the QMP202MP
unit.
2. Connect the power cable (ZZ212025) between the connector
DC Power Input that is marked with a green arrow on the
upper base of the logger tube and the connector DC Power Out
on the QMP202MP unit.
3. Connect the output data cable (ZZ212026) between the
connector PC Connector that is marked with a yellow arrow on
the lower base of the logger tube and the connector PC
Connector on the QMP202MP unit.
Connecting AC Power to
QMP202MP
The AC In connector at the bottom of the QMP202MP unit is
connected either through QPS101 Power Strip to the AC (mains)