Installation Manual _________________________________________________________________
62 __________________________________________________________________ M210485EN-B
The following numbers refer to Figure 45 on page 61:
1 = Foundation bolt
2 = Spring washers, under and above the plate
3 = Washers, under and above the plate
4 = Nuts, under and above the plate
NOTE
The delivered washers may differ from the ones shown in Figure 45
on page 61.
4. Level the pedestal tube to vertical with the nuts that are under
the plate. For adjusting the level, use the appropriate wrench and
a water level to check that the pedestal tube is vertical. Refer to
Figure 46 below.
5. Finally, tighten the bolts with appropriate wrenches.
0303-030
Figure 46 Pedestal Tube Adjustment with Water Level