Installation Manual _________________________________________________________________
80 __________________________________________________________________ M210485EN-B
0303-049
Figure 67 Ground Rod Installation
The following numbers refer to Figure 67 above:
1 = Access well
2 = Grounding rod
3 = Compression lug
4 = Grounding cable
Equipment Grounding
The equipment grounding cable is connected to the equipment ground
system (rod or other) from the one main grounding point, which is
normally a grounding bar located underneath the main system
enclosure.
CAUTION
Always use clamps for connecting a cable to the grounding rod or
two cables together, do not solder.
Consult the local authority for local grounding requirements. A copper
grounding cable and conductive grounding rod(s) are recommended.
Usually, the customer is responsible for supplying grounding cables,
rods, clamps, power cables, long distance signal cables, and conduits
for cables.