28: Configuring SNMP 
_______________________________________________________________________________________________________ 
_____________________________________________________________________________________________________ 
© Virtual Access 2017 
GW1000 Series User Manual 
Issue: 1.9    Page 266 of 350 
Web Field/UCI/Package Option 
Web: System Location 
UCI: snmpd.system[0].sysLocation 
Opt: sysLocation 
Sets the system location, system contact or system name for the 
agent. This information is reported in the ‘system’ group in the 
mibII tree. 
 
Web: System Contact 
UCI: snmpd.system[0].sysContact 
Opt: sysContact 
Web: System Name 
UCI: snmpd.system[0].sysName 
Opt: sysName 
Web: Agent Address 
UCI: snmpd.agent[0].agentaddress 
Opt: agentaddress 
Specifies the address(es) and port(s) on which the agent should 
listen. 
[(udp|tcp):]port[@address][,…] 
Web: Enable Authentication Traps 
UCI: snmpd.agent[0].authtrapenabled 
Opt: authtrapenabled 
Enables or disables SNMP authentication trap. 
Note: this is the SNMP poll authentication trap to be set when 
there is a community mismatch. 
Web: Enable Link State Notification 
UCI: snmpd.agent[0].link_updown_notify 
Opt: link_updown_notify 
Generates trap/info when interface goes up or down. When 
enabled, the router sends a trap notification link up or down. 
Table 90: Information table for system and agent settings 
28.2.2  Com2Sec settings 
To access Com2Sec settings, scroll down the SNMP Services page.  
Use the COM2Sec section to map SNMP community names into an arbitrary security 
name. Map community names into security names based on the community name and 
the source subnet. Use the first source/community combination that matches the 
incoming packet. 
 
Figure 134: The COM2Sec settings