EasyManuals Logo

virtual access GW1000M Series User Manual

virtual access GW1000M Series
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #322 background imageLoading...
Page #322 background image
35: Event system
_______________________________________________________________________________________________________
_____________________________________________________________________________________________________
© Virtual Access 2017
GW1000 Series User Manual
Issue: 1.9 Page 322 of 350
va_eventd.@conn_tester[0].ping_dest_addr=192.168.0.1
va_eventd.@conn_tester[0].ping_source=eth0
va_eventd.@conn_tester[0].ping_success_duration_sec=60
35.7.6.3 Ping connection tester using package options
config conn_tester
option name ‘pinger’
option enabled ‘1’
option type ‘ping’
option ping_dest_addr ‘192.168.0.1’
option ping_source ‘eth0’
option ping_success_duration_sec ‘60’
35.7.6.4 Ping connection tester table options
UCI/Package Option
Description
UCI: va_eventd.<conn_tester
label>.name
Opt: name
Name of this connection tester. This name is referred to by the
target section.
UCI: va_eventd.<conn_tester
label>.enabled
Opt: enabled
Enable this connection tester.
0
Disabled.
1
Enabled
UCI: va_eventd.<conn_tester label>.type
Opt: type
Set to ping for a ping connection tester.
ping
Ping connection tester
link
Link connection tester
UCI: va_eventd.<conn_tester
label>.ping_dest_addr
Opt: ping_dest_addr
IP Address to ping.
UCI: va_eventd.<conn_tester
label>.ping_source
Opt: ping_source
Source IP Address of the pings. This is optional.
It can also be an interface name.
UCI: va_eventd.<conn_tester
label>.ping_success_duration_sec
Opt: ping_success_duration_sec
Defines the time in seconds the target is considered up for after
a successful ping.
Table 115: Information table for ping connection tester settings
35.7.6.5 Link connection tester
A link connection tester tests a connection by checking the status of the interface being used.
35.7.6.6 Link connection tester using UCI
va_eventd.@conn_tester[0]=conn_tester
va_eventd.@conn_tester[0].name=linktest
va_eventd.@conn_tester[0].enabled=1
va_eventd.@conn_tester[0].type=link
va_eventd.@conn_tester[0].link_iface=eth0
Link connection tester using package options

Table of Contents

Other manuals for virtual access GW1000M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the virtual access GW1000M Series and is the answer not in the manual?

virtual access GW1000M Series Specifications

General IconGeneral
Brandvirtual access
ModelGW1000M Series
CategoryNetwork Router
LanguageEnglish