5-16 BA 901/1101 en – Edition 2.1 * 91101b520.fm
Maintenance
• If the attachment is not positioned as shown:
☞ Start the engine and let it run at idling speed
☞ Retract the cylinders of the loader unit, lower the bucket to the ground
☞ Stop the engine again.
☞ Proceed as follows:
• Park the machine on level ground
• Retract the cylinders of the loader unit, lower the bucket to the ground
• Stop the engine
• Raise the safety bar
• Open the engine cover
• Sight glass A is located on hydraulic oil reservoir
• Check the oil level on sight glass A
• The oil level must be at the FULL level
If the oil level is lower
• Add hydraulic oil
The oil level varies according to the machine’s operating temperature:
Measure the oil level of the hydraulic system only after the machine reaches its
operating temperature.
1
Fig. 102: Parking the loader
Fig. 103: Oil level indicator on the hydraulic oil reservoir
FULL
LOW
A
Machine condition Temperature Oil level
• Before putting into operation
Between 10 and 30 °C LOW mark
• Normal operation
Between 50 and 90 °C FULL mark