EasyManua.ls Logo

Wilo FK 17.1 - Maintenance Intervals; Maintenance Measures

Wilo FK 17.1
1364 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en Maintenance and repair
182 WILO SE 2019-01
9.4.1 Oil types
Medicinal white oil is filled into the sealing chamber ex-factory. The following oil types
are recommended when changing the oil:
Aral Autin PL*
Shell ONDINA 919
Esso MARCOL 52* or 82*
BP WHITEMORE WOM 14*
Texaco Pharmaceutical 30* or 40*
All oil types marked with “*” are approved for use with foods in accordance with
“USDA-H1”.
9.4.2 Grease
Use the following greases:
Esso Unirex N3
Tripol Molub-Alloy-Food Proof 823 FM (with “USDA-H1” approval)
9.4.3 Filling quantities
Refer to the supplied configuration for the filling quantities.
9.5 Maintenance intervals
To ensure reliable operation, maintenance tasks must be carried out regularly. Depend-
ing on the real ambient temperatures, maintenance intervals different from those men-
tioned in the contract can be defined! If strong vibrations occur during operation, the
pump and the installation must be checked regardless of the defined maintenance in-
tervals.
9.5.1 Maintenance intervals for normal
conditions
8000operating hours or after 2years at the latest
Visual inspection of the connection cable
Visual inspection of accessories
Visual inspection of the coating and housing for wear
Function test of monitoring devices
Oil change
Motor compartment
Sealing chamber
NOTICE!If a sealing chamber control is installed, the oil is changed according to the
indicator!
15000operating hours or after 10years at the latest
General overhaul
9.5.2 Maintenance intervals for harsh
conditions
Under harsh operating conditions, specified maintenance intervals must be shortened if
required. Harsh operating conditions include:
Fluids with long-fibre components
Turbulent inlet (e.g. due to air intake, cavitation)
Strongly corroding or abrasive fluids
Heavily gas generating fluids
Operation at an unfavourable duty point
Pressure surges
When using pumps under hard conditions, it is recommended to sign a maintenance
contract. Contact customer service.
9.6 Maintenance measures
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.