Troubleshooting Guide
Electrical Problems
Troubleshooting Guide 60HDdoc102619 6-4
6
PROBLEM CAUSE SOLUTION
Up/Down Or Power Feed
Motors Overheat And Lose
Power.
System overload or bind
occurred.
Correct problem (See Section 6.3 ). Allow
motor to cool before restarting.
Normal operation factors
exceeded (eg: up/down control
jockeyed excessively).
Allow motor to cool before restarting.
Everything Works And Then
Cuts Out - Works Again.
Bad battery, fuse, or ground
connection.
Check and tighten connections.
Nothing Works Electrically. Dead battery. Check for short circuit or turn OFF key.
Blown fuse. Replace.
Corrosion on battery post. Remove connection and clean posts.
Loose connections at LED cir-
cuit board or alternator.
Check and tighten connections.
Intermittent Or Permanent
Loss Of Accessory Motor
Functions Occurs
(Up/down, Fwd/rev, Blade
Guide Functions Do Not
Work).
Bad connections at accessory
solenoid or bad solenoid.
Check all connections at accessory solenoid.
If connections are good, replace solenoid.