EasyManua.ls Logo

Xerox Versant 3100 Press - Page 113

Xerox Versant 3100 Press
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Push the black connector in until it clicks into place.
Note
The three white connectors are keyed and cannot be mixed up. The smallest connector
is in the back and the largest is in the front.
Note
Notice that the small white connector with the two black wires does not need to be
connected for this configuration.
6. Gently close the Fuser Top Cover. Reinstall the two larger screws using the T15 Torx
driver.
Note
You must reinstall the Front Fuser Cover.
7. Replace and secure the Fuser Front Cover with the smaller T10 screw.
Warning
You must push the drawer in. Pulling the drawer further out will disengage it from
the rails resulting in damage to the drawer and possible personal injury.
8. To push in and close the Transfer Drawer, press the rail tabs on each side of the
drawer with your fingers as you gently push the drawer into the press.
9. Latch the Transfer Drawer and close the press left and center front doors to complete
the procedure.
10. Ask the administrator to reset the High Frequency Service Item (HFSI) count for this
newly-replaced CRU component. The HFSI components that need to be reset at the
press touch screen are:
Belt Module 1 (No Fuser connector)
Belt Module 2 (Fuser connector 1)
Belt Module 3 (Fuser connector 2)
6-37Xerox
®
Versant
®
3100 Press
User Guide
Maintenance

Table of Contents

Other manuals for Xerox Versant 3100 Press

Related product manuals