a) Remove the separator roll by squeezing the metal shaft at both ends and lifting
it up and out of the tray.
b) Install a new separator roll by squeezing the metal shaft at both ends and sliding
it into place.
6. Close the bypass tray cover.
7. Verify that the tray is operating correctly by feeding paper from the bypass tray.
8. Either log in as the administrator or ask the administrator to perform the following
steps to reset the High Frequency Service Item (HFSI) count to zero (0):
a) At the control panel, press the Tools button.
b) From the screen that displays, select the Tools icon.
c) Select System Settings > Common Service Settings > Maintenance.
d) Use the up / down arrow buttons to access the next Maintenance screens.
e) Select the Technical Key Operator icon. The Technical Key Operator feature
displays.
f) Select the bypass roll items that corresponds with the newly-replaced components.
g) Select Reset Current Value. The system resets the High Frequency Service Item
(HFSI) to 0.
h) Exit the administrator mode by pressing the Log In / Out button on the control
panel. When prompted, select Logout.
6-15Xerox
®
Versant
®
3100 Press
User Guide
Maintenance