SonTek – a Xylem brand
FlowTracker2 User’s Manual (January 2019)
275
14.9. Post-Processing FlowTracker Measurements
A powerful new feature in the FlowTracker2 now allows the user to edit most values
associated with a measurement after the measurement is taken. This section provides
instructions on the post-processing ability of the FlowTracker2 software.
Measurements taken with the Original FlowTracker Handheld ADV can also be edited
with the FlowTracker2 software.
Enable Editing 14.9.1
FlowTracker2 .ft File Editing 14.9.1.1
By default, any measurement taken with the FlowTracker2 will have editing enabled.
The editing pane appears in the top right corner of the software, shown in Figure 14:33.
Figure 14:33. FlowTracker 2 Editing Buttons
Functions include:
• Apply Settings and Recompute Discharge – after any changes in the Settings
Pane (right pane), hitting this button will apply those changes and recalculate
discharge.
Recompute Discharge
Editing