49
Tilt Angle Warning 3.4.3.5
The Tilt Angle Warning parameter is the maximum threshold placed on the tilt angle of
the wading rod.
a) An angle of 0° means the wading rod is vertical (as desired for an ideal mounting
position).
b) The default Tilt Angle Warning applied in FlowTracker2 is 5 degrees.
c) To change the Tilt Angle Warning,
i). Use the backspace key to clear current entry,
ii). Type in the new value using the keypad.
d) To DISABLE the Tilt Angle Warning,
i). Use the backspace key to clear current entry until “Disabled” is displayed.
Discharge Settings 3.4.4
The Discharge Settings function contains parameters required for discharge
calculations, discharge uncertainty analysis and quality control process.
Discharge settings function is only applicable to the Discharge Mode. The General
Mode does not contain any discharge calculation or uncertainty analysis.
Discharge Settings screen includes the following
parameters,
a) Discharge Equation,
b) Discharge Uncertainty,
c) Discharge Reference,
d) Max Station Q for Warning,
e) Max Depth Change for Warning,
f) Max Spacing Change for Warning.
g) 0.6 Method Depth
h) To select a parameter,
i). Use up or down scroll arrows keys to select a
parameter,
ii). The parameter selected will be highlighted in
yellow.
i) To navigate to Template Menu,
i). Press the Left Soft Key.
Figure 3:14 - Discharge Settings
Properties associated with the parameters in discharge settings are defined in Table
3:10,
Table 3-10 - Discharge Settings - Properties
Parameter
Min
Max
Default
Units
Required
Max Station Q for Warning
0.01
100
10
%
Yes

Table of Contents