3 - 38
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
4. Disconnect:
battery leads
(from the battery terminals)
CAUTION:
_
First, disconnect the negative battery lead
1
, and then positive battery lead
2
.
5. Remove:
battery 3
6. Disconnect:
battery breather hose 1 4
battery breather hose 2 5
3
1
2
4
5
4
5
7. Check:
electrolyte level
The electrolyte level should be between the
minimum level mark a and the maximum
level mark b.
Below the minimum level mark Add dis-
tilled water to the proper level.
CAUTION:
_
Add only distilled water. Tap water con-
tains minerals which are harmful to the bat-
tery.
8. Check:
specific gravity
Less than 1.280 Recharge the battery.
F
Specific gravity
1.280 at 20 °C (68 °F)