11-24
11
COMMUNICATION WITH PC
11-5 Communication Command Description
(14)
@?EMG
Reads the emergency stop status.
Transmission example : @?EMG c/r l/f
Response example 1 : 0 c/r l/f .......................................... Emergency stop is off.
OK c/r l/f
Response example 2 : 1 c/r l/f .......................................... Emergency stop is on.
OK c/r l/f
(15)
@?SRVO [<axis>]
Reads the servo state of all axes or a specified axis.
When all axes are specified, the response results in "1" only when the servo of all axes has been
on.
Axis : "0" for all axes, "1" for the X-axis, and "2" for the Y-axis.
If this setting is omitted, all axes are selected.
Transmission example : @?SRVO c/r l/f
Response example 1 : 0 c/r l/f .......................................... Servo is off.
OK c/r l/f
Response example 2 : 1 c/r l/f .......................................... Servo is on.
OK c/r l/f
(16)
@?ORG [<axis>]
Reads whether or not return-to-origin has been completed on all axes or specified axis.
When all axes are specified, the response results in "1" only when return-to-origin has been
completed on all axes.
Axis : "0" for all axes, "1" for the X-axis, and "2" for the Y-axis.
If this setting is omitted, all axes are selected.
Transmission example : @?ORG c/r l/f
Response example 1 : 0 c/r l/f .......................................... Return-to-origin not com-
pleted.
OK c/r l/f
Response example 2 : 1 c/r l/f .......................................... Return-to-origin completed.
OK c/r l/f
(17)
@?XGRDP
Reads the X-axis grid position (machine reference when return-to-origin is completed).
Transmission example : @?XGRDP c/r 1/f
Response example : 50% c/r 1/f
OK c/r l/f
c
CAUTION
The response value will be meaningless if return-to-origin is not completed. Always transmit the command after
return-to-origin has been completed.