7. BP Variable number/LBP Variable number/BP [Array
number]/LBP [Array number]
When a BP Variable number, LBP Variable number, BP [Array number], or
LBP [Array number] is selected from the table in part 1 of this Explanation,
add the following tag.
8. EX Variable number/LEX Variable number/EX [Array
number]/LEX [Array number]
When an EX Variable number, LEX Variable number, EX [Array number],
or LEX [Array number] is selected from the table in part 1 of this
Explanation, add the following tag.
(1) SUB B000 10
Subtracts 10 from B000, and stores the result in B000.
(2) SUB I000 I001
Subtracts I001 from I000, and stores the result in I000.
(3) SUB P000 P001
Subtracts P001 from P000, and stores the result in P000.
No. Tag Explanation Note
29 BP Variable number/
LBP Variable
number/
BP [Array number]/
LBP [Array number]
Specifies the number of the base axis position type
variable to be subtracted.
<Data 2>
No. Tag Explanation Note
30 EX Variable number/
LEX Variable
number/
EX [Array number]/
LEX [Array number]
Specifies the number of the station axis position type
variable to be subtracted.
<Data 2>