2 INFORM Explanation
FS100 2.1 I/O Instructions : WAIT
2-8
2. =
When an IN# (input number), OT# (output number), SIN# (specific input
number), or SOUT# (specific output number) is selected from the table in
part 1 of this Explanation, add the following tag.
3. B Variable number /LB Variable number / B [Array
number] / LB [Array number] / ON / OFF
When an IN# (input number), OT#(output number), SIN# (specific input
number), or
SOUT# (specific output number) is selected from the table in part 1 of this
Explanation, choose one of the tags from the following table.
5 IG#(Input group
number)
Specifies the number of general input group (1 group 8
points) signal for the waiting condition.
No:1 to 128
Variable B/I/D/LB/LI/LD
can be used.
6 OG#(Output group
number)
Specifies the number of general output group (1 group
8 points) signal for the waiting condition.
No:1 to 128
Variable B/I/D/LB/LI/LD
can be used.
7 IGH#(Input group
number)
Specifies the number of general input group (1 group 4
points) signal for the waiting condition.
No:1 to 256
Variable B/I/D/LB/LI/LD
can be used.
8 OGH#(Output group
number)
Specifies the number of general output group (1 group4
points) signal for the waiting condition.
No:1 to 256
Variable B/I/D/LB/LI/LD
can be used.
9 B Variable number/
LB Variable number/
B [Array number]/
LB [Array number]
Specifies the byte type variable for the waiting
condition.
No Tag Explanation Note
No Tag Explanation Note
10 = It is equal.
No Tag Explanation Note
11 B Variable number/
LB Variable number/
B [Array number]/
LB [Array number]
Specifies byte type variable which becomes a waiting
condition.
Least significant bit:
0:OFF
1:ON
12 ON/OFF Specifies on/off of the waiting condition.