2 INFORM Explanation
FS100 2.1 I/O Instructions : WAIT
2-9
4. =/<>
When an IG# (input group number), OG# (output group number), IGH#
(input group number), OGH# (output group number), B variable number,
LB variable number, B [array number], or LB [array number] is selected
from the table in part 1 of this Explanation, choose one of the tags from the
following table.
5. B Variable number / LB Variable number / B [Array
number] / LB [Array number] / Byte type constant
When an IG# (input group number), OG# (output group number), IGH#
(input group number), OGH# (output group number), B variable number,
LB variable number, B [array number], or LB [array number] is selected
from the table in part 1 of this Explanation, choose one of the tags from the
following table.
6. T=time
The following tag can be added or omitted.
No Tag Explanation Note
13 = It is equal.
14 <> It is not equal.
No Tag Explanation Note
15 B Variable number/
LB Variable number/
B [Array number]/
LB [Array number]
Specifies byte type variable which becomes a waiting
condition.
16 Byte type constant The waiting condition is specified by byte type constant.
No Tag Explanation Note
17 T=time Specify the waiting time.
When the time specified here ends, if the status and the
condition are not the same, the next instruction is
executed.
Time: 0 to 65.535
seconds
It is possible to specify at
time by the I/LI/I/LI
variable (Units: 0.001
seconds).