5-44
Analog Reference Card: F2
User parameters for the Analog Reference Card are shown in the following table.
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
F1-23
PG Gear Teeth
Count 1
Sets the number of gear teeth
(deceleration ratio) between
Motor-2 and the pulse generator.
[(RPMs x 60)/PGpulseCount]
x (F1-24)/(F1-23)
If either value is zero, then
the decleration ratio will
equal "1".
0
to
1000
0 No No A No No No 3B2H
PG Gear
Teeth1
F1-24
PG Gear Teeth
Count 2
0
to
1000
0 No No A No No No 3B3H
PGO Gear
Teeth2
F1-25
Hardware
Disconnected
Detection
Selection CH1
Enables or disables the drive
from detecting when the PG
option on CH1 has been
disconnected.
0: Disabled.
1: Enabled.
When using PG-T2 or Z2,
this setting is enabled.
0 to 1 1 No No A No A No 3B4H
HW PGO ch1
F1-26
Hardware
Disconnected
Detection
Selection CH2
0 to 1 1 No No A No A No 3B5H
HW PGO ch2
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
2
F2-01
AI-14 Input
Selection
Sets the function for channel
1 to 3 of the AI-14B analog
input reference option board.
0: 3-channel individual
(Channel 1: terminal A1,
Channel 2: terminal A2,
Channel 3: terminal A3)
1: 3-channel addition
(Summed values of
channels 1 to 3 is the
frequency reference)
When set to 0, select 1 for
b1-01. In this case, the
multi-function input "Option/
Inverter selection" cannot be
used.
0 or 1 0 No A A A A A 38FH
AI-14 Input