5-88
U1-13
Cumulative
Operation
Time
Total operating or power-on
time of the Drive.
No output possible.
1
hr
AA A A A 4CH
Elapsed
Time
U1-14
Software
Number
Last 5 digits of the Drive's
software number.
No output possible. - A A A A A 4DH
FLASH ID
U1-15
Terminal
A1 Input
Voltage
Input voltage on Terminal A1,
as a percentage of ±10Vdc.
10V: 100% (when input is 10V)
(possible for -10V thru +10V)
0.1
%
AA A A A 4EH
Term A1
Level
U1-16
Terminal
A2 Input
Voltage
Displays the input current (or
voltage) on Terminal A2, as a
percentage of ±10Vdc.
10V: 100% (when input is 10V)
(possible for -10V thru +10V)
0.1
%
AA A A A 4FH
Term A2
Level
U1-17
Terminal
A3 Input
Voltage
Input voltage on Terminal A3,
as a percentage of ±10Vdc.
10V: 100% (when input is 10V)
(possible for -10V thru +10V)
0.1
%
AA A A A 050H
Term 16
Level
U1-18
Motor
Secondary
Current (Iq)
Current being used by the
motor to produce torque (Iq).
10V: Motor Rated Secondary
Current
(possible for -10V thru +10V)
0.1
%
AA A A A 51H
Mot SEC
Current
U1-19
Motor
Excitation
Current (Id)
Current being used by the
motor for excitation (Id).
10V: Motor Rated Secondary
Current
(possible for -10V thru
+10V)
0.1
%
No No A A A 52H
Mot EXC
Current
U1-20
Output
Frequency
After Soft
Start
Frequency reference (speed
command) after the accel and
decel ramps and S-curve.
10V: Maximum Frequency
(possible for -10V thru +10V)
0.0
1Hz
AA A A A 53H
SFS Output
U1-21
ASR Input Input error to the speed control
loop (ASR).
The maximum output
frequency E1-04 corresponds
to 100%.
10V: Maximum Frequency
(possible for -10V thru +10V)
0.0
1%
No A No A A 54H
ASR Input
U1-22
ASR
Output
Output from the speed control
loop (ASR).
The motor rated secondary
current corresponds to 100%.
10V: Motor Rated Secondary
Current
(possible for -10V thru +10V)
0.0
1%
No A No A A 55H
ASR
Output
Parameter
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2