User Parameter Tables
5-93
Note The following errors are not included in the error trace: CPF00, 01, 02, 03, UV1, and UV2.
U2-10
Torque
Reference at
Previous
Fault
Gives the torque reference at the
most recent fault.
No output possible.
0.1% No No A No A 89H
Torque
Reference
U2-11
Input
Terminal
Status at
Previous
Fault
Shows the input terminal status at
the most recent fault.
-AAAAA 8AH
Input Term
Sts
U2-12
Output
Terminal
Status at
Previous
Fault
Gives the output terminal status
at the most recent fault.
-AAAAA 8BH
Output Term
Sts
U2-13
Drive
Operation
Status at
Previous
Fault
Displays the Drive Operation
Status at the most recent fault.
-AAAAA 8CH
Inverter
Status
U2-14
Cumulative
Operation
Time at
Previous
Fault
Gives the cumulative operation
time at the previous fault.
1
hr
AA A A A 8DH
Elapsed time
Parameter
Number
Name
Description
Output Signal
Level During
Multi-Function
Analog Output
Min.
Unit
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2