EasyManua.ls Logo

YASKAWA G7 Series - Page 224

YASKAWA G7 Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-6
Setting Precautions
When setting analog inputs to step 1 to step 3, observe the following precautions.
When setting terminal A1's analog input to step 1, set b1-01 to 1, and when setting d1-01 (Frequency Ref-
erence 1) to step 1, set b1-01 to 0.
When setting terminal A2's analog input to step 2, set H3-09 to 2 (auxiliary frequency reference). When
setting d1-02 (Frequency Reference 2) to step 2, set H3-09 to 1F (do not use analog inputs).
When setting terminal A3's analog input to step 3, set H3-05 to 3 (auxiliary frequency reference 2). When
setting d1-03(Frequency Reference 3) to step 3, set H3-05 to 1F (Analog input not used).
Connection Example and Time Chart
The following diagram shows a time chart and control circuit terminal connection example during a 9-step
operation.
Fig 6.6 Control Circuit Terminal During 9-step Operation
Fig 6.7 Multi-step speed reference/Jog Frequency Selection Time Chart
Drive
S1 Forward/stop
S2 Reverse/stop
S3 External fault
S4 Fault reset
S5 Multi-step speed reference 1
S6 Multi-step speed reference 2
S7 Multi-step speed reference 3
SC Sequence common
S8 Jog frequency
Forward/stop
Multi-step speed
reference 1
Multi-step speed
reference 2
Multi-step speed
reference 3
Jog frequency
selection
Frequency
reference 3
Frequency
reference 4
Frequency
reference 5
Frequency
reference 6
Jog frequency
Frequency
reference 8
Frequency
reference 7
Frequency
reference
Frequency
reference 1:
Master speed
frequency
Frequency
reference 2:
Auxiliary speed
frequency