7-14
OPE10
V/f Ptrn Set-
ting
V/f data setting error
Parameters E1-04, E1-06, E1-07, and E1-09 do not satisfy the following conditions:
E1-04 (FMAX) E1-06 (FA) > E1-07 (FB) E1-09 (FMIN)
E3-02 (FMAX) E3-04 (FA) > E3-05 (FB) E3-07 (FMIN)
OPE11
Carr Freq/
On-Delay
Parameter setting error
One of the following parameter setting errors exists.
C6-05 (Carrier Frequency Gain) > 6, the Carrier Frequency Lower Limit (C6-04)
> the Carrier Frequency Gain(C6-05)
Upper/lower limit error in C6-03 to 05.
C6-01 is 0 and C6-02 is 2 to E.
C6-01 is 1 and C6-02 is 7 to E.
ERR
EEPROM
R/W Err
EEPROM write error
A verification error occurred when writing EEPROM.
Try turning the power supply off and on again.
Try setting the parameters again.