1.21 Defaults by Drive Model and Duty Rating ND/HD
150 YASKAWA TOEPYAIGA8002B GA800 Drive Programming
No. Name Unit Default
- Drive Model - 4605 4720
C6-01
Normal / Heavy Duty
Selection
-
HD ND HD ND
0 1 0 1
o2-04
Drive Model (KVA)
Selection
Hex. AE AF
E2-11
(E4-11, E5-02)
Motor Rated Power HP (kW)
400
(315)
450
(355)
400
(315)
500
(370)
E2-06
(E4-06)
Motor Leakage
Inductance
% 20 20 20 20
E2-10
(E4-10)
Motor Iron Loss W 4700 5560 4700 5560
E5-01
PM Motor Code
Selection
- FFFF FFFF FFFF FFFF
L2-02
Power Loss Ride
Through Time
s 2 2 2 2
L2-03
Minimum Baseblock
Time
s 2.1 2.3 2.1 2.3
L2-04
Powerloss V/f Recovery
Ramp Time
s 2 2.2 2 2.2
L2-05
Undervoltage Detection
Lvl (Uv1)
- 380 380 380 380
L3-24
Motor Accel Time for
Inertia Cal
s 1.392 1.667 1.392 1.667
L8-02 Overheat Alarm Level °C 133 133 125 125
L8-09
Output Ground Fault
Detection
- 1 1 1 1
L8-38
Carrier Frequency
Reduction
- 2 2 2 2
n1-01
Hunting Prevention
Selection
- 2 2 2 2
n1-03
Hunting Prevention
Time Constant
ms 100 100 100 100
n5-02
Motor Inertia
Acceleration Time
s 1.392 1.667 1.392 1.667
*1 Parameters within parentheses are for motor 2.