Parameter Details
2
2.4 C: Tuning
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 263
Table 2.32 Example Settings of MFAO Terminals to Monitor Speed Waveforms
No. Name Setting Value Description
H4-01 Terminal FM Analog Output Select 116 Lets you use terminal FM to monitor U1-16
[SFS Output Frequency].
H4-02 Terminal FM Analog Output Gain 100.0%
H4-03 Terminal FM Analog Output Bias 0.0%
H4-04 Terminal AM Analog Output Select 105 Lets you use the terminal AM to monitor
U1-05 [Motor Speed].
H4-05 Terminal AM Analog Output Gain 50.0%
H4-06 Terminal AM Analog Output Bias 0.0%
H4-07 Terminal FM Signal Level Select 1 Lets you monitor in a -10 to +10 V range.
H4-08 Terminal AM Signal Level Select 1
These settings cause this MFAO configuration. The MFAO common is terminal AC:
Terminal FM: Outputs the output frequency after SFS in a -10 V to +10 V (-100% to +100%) range.
Terminal AM: Outputs the motor speed in a -10 V to +10 V (-200% to +200%) range.
Yaskawa recommends that you monitor the output frequency after SFS and the motor speed for delays in response
and differences in reference values.
Adjust ASR Parameters
Use Table 2.33 to adjust ASR. The table shows the parameters for motor 1. To operate motor 2, set the motor 2
parameters in the same method.
Note:
When adjusting the proportional gain and integral time, adjust the proportional gain first.
Table 2.33 ASR Response and Possible Solutions
Problem Possible Solutions
Speed response is slow.
Increase C5-01/C5-03 [ASR Proportional Gain].
Decrease C5-02/C5-04 [ASR Integral Time].
Overshoot or undershoot occurs at the end of acceleration
or deceleration.
Decrease C5-01/C5-03.
Increase C5-02/C5-04.
Vibration and oscillation occur at constant speed.
Decrease C5-01/C5-03.
Increase C5-02/C5-04.
Increase C5-06 [ASR Delay Time].
Speed accuracy is unsatisfactory when you operate a motor
that has a large quantity of rated slip in Closed Loop V/f
Control.
Check the pulse number set to F1-01 [Encoder 1 Pulse
Count (PPR)] and the gear ratio set to F1-12 [Encoder 1
Gear Teeth 1] and F1-13 [Encoder 1 Gear Teeth 2].
Make sure that you correctly set the pulse signal from
the encoder.
Check U6-04 [ASR Output] to make sure that the ASR
operates at its output limit set to C5-05 [ASR Limit]. If
the ASR is at the output limit, increase C5-05.