2.8 H: Terminal Functions
406 YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Drives have three analog input terminals, terminals A1, A2, and A3. H3 parameters select the functions set to these
analog input terminals and adjust signal levels.
Table 2.64 shows the functions that you can set to analog input terminals. Use H3-02, H3-06, and H3-10 [MFAI
Function Selection] to set functions.
Table 2.64 MFAI Setting Values
Setting
Value
Function Ref.
0 Frequency Reference 413
1 Frequency Gain 413
2 Auxiliary Frequency Reference 1 413
3 Auxiliary Frequency Reference 2 414
4 Output Voltage Bias 414
5 Accel/Decel Time Gain 414
6 DC Injection Braking Current 414
7 Torque Detection Level 415
8 Stall Prevent Level During Run 415
9 Output Frequency Lower Limit 415
B PID Feedback 415
C PID Setpoint 416
D Frequency Bias 416
Setting
Value
Function Ref.
E Motor Temperature (PTC Input) 416
F Not Used 416
10 Forward Torque Limit 416
11 Reverse Torque Limit 417
12 Regenerative Torque Limit 418
13 Torque Reference / Torque Limit 418
14 Torque Compensation 418
15 General Torque Limit 418
16 Differential PID Feedback 418
1F Not Used 418
30 DWEZ Analog Input 1 418
31 DWEZ Analog Input 2 418
32 DWEZ Analog Input 3 419
Note:
All analog input scaling uses gain and bias for adjustment. Set the gain and bias values correctly.