4.3
SVB-01 Module Parameter Details
4-31
( 11 ) Speed Reference
OW

0E
Speed Limit at Torque
Reference
Setting Range Setting Unit Default Value
32768 to 32767
0.01% 15000
Set the speed limit for torque references as a percentage of the rated speed.
Torque control is used to control the Servomotor to output the specified torque, so it does not control the motor speed. Therefore,
when an excessive reference torque is set relative to the load torque of the machine, the machine’s torque is overpowered by the
torque reference and the motor speed rapidly increases. The Speed Limit at Torque Reference functions to limit the Servomotor
speed during torque control to protect the machine.
         
No speed limit
                
Speed limit used
Either the Speed Limit at Torque Reference (OW

0E) or SERVOPACK’s Torque Control Speed Limit (Pn407) is effective,
whichever is lower.
Related Parameters
(cont’d)
Position
Phase
Speed
Torque
0
t
Speed
The high rate of acceleration
may damage the machine.
Maximum
speed
0
t
Speed
Limited
speed
The speed limit
prevents damage.
Maximum
speed
SGDS, SGDH+NS115, SGDH+NS110 SGD-N, SGDB-N
Pn002.1
Pn407
Pn408.1
Pn300
Cn-02, bit 2
Cn-14
Cn-03
OL

10
Speed Reference
Setting Range Setting Unit Default Value
2
31
to 2
31
1
Depends on the Speed Units
set in Function 1 (setting
parameter OW

03, bits 0 to
3).
3000
Set the speed reference.
This parameter is used by the following commands.
1: POSING Positioning
2: EX_POSING External Positioning
3: ZRET Zero Point Return
7
:
FEED
JOG operation
8: STEP STEP operation
23: VELO Speed Reference
25
:
PHASE
Phase Reference
Refer to Chapter 5 Motion Commands for details.
Position
Phase
Speed
Torque
WWW.NNC.IR