9-4
IM 701510-01E
Setting up the determination conditions
23. Press the “Setup” soft key of the GO/NO-GO top menu. The condition setup menu will
appear.
24. After having selected the “Mode” setting of the trace to be measured using the rotary
knob, press the SELECT key to select “ON”. Pressing the key once again results in
selecting “OFF”, and no waveform determination will occur.
25. After having selected the “Condition” setting of the same trace using the rotary knob,
press the SELECT key to select the desired condition. When the condition is met,
“NO-GO” will result.
“OUT” : The waveform under measurement protrudes from the determination zone;
“IN” : The waveform under measurement enters the determination zone.
26. Repeat steps 24 and 25 for other traces if necessary.
Selecting AND or OR determination : Logic
27. After having selected the “Logic” setting on the condition setup menu, press the
SELECT key to select the desired condition. When the condition is met, “NO-GO” will
result.
“AND” : All determinations are “NO-GO”
“IN” : Any of the determination is “NO-GO”
Sequence determination
28. After having selected the “Sequence” setting on the condition setup menu, press the
SELECT key to select the desired sequence. The following types can be selected.
“SINGLE” : Stops determination when a “NO-GO” determination is made
“CONTINUE” : Carries out determination repeatedly until the “ABORT” soft key is
pressed
Setting action after determination
29. After having selected the “Action” setting on the condition setup menu, press the
SELECT key to select the desired action. After a “NO-GO” determination, the data can
be recorded in the following manners.
“NONE” : No action;
“PRINT” : A hardcopy of the screen will be printed out on the built-in printer;
“FD(P-P)” : All waveforms displayed on the screen will be saved to the floppy disk
as P-P compressed data;
“FD(ACQ)” : Acquisition data of all waveforms displayed on the screen will be saved
to the floppy disk as binary data.
30. After having selected either “FD(P-P)” or “FD(ACQ)”, move to the
FileName”setting and press the SELECT key. The keyboard will be displayed. After
having selected either “NONE” or “PRINT”, continue with step 32.
31. Use the keyboard to enter the name of the file. The entered filename will be displayed at
the “FileName”setting. For details how to operate the keyboard, refer to page 4-8.
Returning to the top menu
32. Return to the GO/NO-GO top menu by pressing the ESC key.
9.1 Judging using a Waveform Zone

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL 1540 and is the answer not in the manual?

YOKOGAWA DL 1540 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL 1540
CategoryTest Equipment
LanguageEnglish

Related product manuals