86 Z4Mplus and Z6Mplus User Guide
Routine Care and Adjustments
Cleaning Procedures
Cleaning Procedures
Specific cleaning procedures are provided on the following pages. Below is a
recommended cleaning schedule.
.
Area Method Interval
Printhead Solvent* Direct Thermal Mode: After
every roll of media (or 500 feet of
fanfold media).
Thermal Transfer Mode: After
every roll of ribbon or three rolls of
media.
These intervals are intended as
guidelines only. You may have to
clean more often, depending upon
your application and media.
Platen roller Solvent*
Media sensors Air blow
Ribbon sensor Air blow
Media path Solvent*
Ribbon path Solvent*
Pinch roller. (Optional peel-
off option required. Refer to
page 92.)
Solvent*
Cutter
Module
If cutting
continuous,
pressure-sensitive
media
Solvent* After every roll of media (or more
often, depending upon your
application and media).
If cutting tag stock
or label liner
material
Solvent*
and air
blow
After every two or three rolls of
media.
Tear-off/peel-off bar Solvent* Once a month.
Take label sensor Air blow Once every six months.
* Zebra recommends using the Preventive Maintenance Kit, Part Number 47362 or a solution of 90% Isopropyl and 10%
deionized water)
Note • Zebra Technologies Corporation will not be responsible for damage caused
by the use of cleaning fluids on the Z4Mplus/Z6Mplus printer.

Table of Contents

Other manuals for Zebra Z4Mplus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra Z4Mplus and is the answer not in the manual?

Zebra Z4Mplus Specifications

General IconGeneral
Print MethodThermal transfer or direct thermal
Resolution203 dpi
Max Print Width4.09 inches
Max Print Length39 inches
Max Print Speed10 inches per second
Memory4 MB Flash, 8 MB DRAM
InterfaceParallel, Serial
Media SensorsReflective and transmissive
Media Width0.79 inches to 4.5 inches
Media Length0.38" (9.6 mm) to 39" (991 mm)
Ribbon Width2 inches to 4.33 inches
Power Requirements100-240 VAC, 50/60 Hz
Operating Temperature40°F to 105°F
Storage Temperature-40 to 140°F (-40 to 60°C)
Humidity20 to 85% non-condensing