Actual signals and parameters 263
DI2 See selection DI1.2
DI3 See selection DI1.3
DI4 See selection DI1.4
DI5 See selection DI1.5
RESET Reset loggers. Parameter is set to NOT SEL. 7
DI1(INV) Reset loggers on the falling edge of DI1. -1
DI2(INV) See selection DI1(INV).-2
DI3(INV) See selection DI1(INV).-3
DI4(INV) See selection DI1(INV).-4
DI5(INV) See selection DI1(INV).-5
6404 AL2 SIGNAL Defines the signal logged for amplitude logger 2 103
x…x Parameter index in group 01 OPERATING DATA. Eg 102 =
0102 SPEED.
1 = 1
6405 AL2 SIGNAL
BASE
Defines the base value from which the percentage
distribution is calculated. Representation and default value
depends on the signal selected with parameter 6404 AL2
SIGNAL.
-
-- -
6406 PEAK VALUE Detected peak value of the signal selected with parameter
6401 PVL SIGNAL
-
-- -
6407 PEAK TIME 1 Date of the peak value detection -
0…65535 d Day on which the peak value was detected.
Format: Date if the real time clock is operating. / The
number of days elapsed after the power-on if the real time
clock is not used, or was not set.
1 = 1 d
6408 PEAK TIME 2 Time of the peak value detection -
00:00:00…
23:59:58
hours:minutes:seconds 1 = 2 s
6409 CURRENT AT
PEAK
Current at the moment of the peak value -
0.0…6553.5 A 1 = 0.1 A
6410 UDC AT PEAK DC voltage at the moment of the peak value -
0…65535 V 1 = 1 V
6411 FREQ AT
PEAK
Output frequency at the moment of the peak value -
0.0…6553.5 Hz 1 = 0.1 Hz
6412 TIME OF
RESET 1
Last reset date of the peak logger and amplitude logger 2 -
0…65535 d Day of the last reset.
Format: Date if the real time clock is operating. / The
number of days elapsed after the power-on if the real time
clock is not used, or was not set.
1 = 1 d
6413 TIME OF
RESET 2
Last reset time of the peak logger and amplitude logger 2 -
All parameters
No. Name/Value Description Def/FbEq