Inspecting the oil level in axis-3 gearbox
Use this procedure to inspect the oil level in the gearbox.
NoteAction
xx2100002068
Floor-mounted robot:
Jog the robot into position:
Axis 1: no significance
Axis 2:
Axis 3: +10°
Axis 4: no significance
Axis 5: no significance
Axis 6: no significance
1
xx2100002069
Option Inverted (3317-1)
Jog the robot into position:
Axis 1: no significance
Axis 2:
Axis 3: -170°
Axis 4: no significance
Axis 5: no significance
Axis 6: no significance
2
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
3
Make sure that the oil temperature is +25°C
± 10°C.
4
WARNING
Handling gearbox oil involves several
safety risks, see Gearbox lubricants (oil or
grease) on page 29.
5