NoteAction
Check the o-ring grooves.3
The grooves must be geometrically correct and
should be free of pores and contamination.
Lubricate the o-ring with grease.4
Tighten the screws evenly while assembling.5
Check that the o-ring is not squashed outside
the o-ring groove.
6
Product manual - IRB 5720 193
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.2.3 Mounting instructions for sealings