NoteAction
xx2100002168
Remove the turning disc.2
Refitting the turning disc
Use these procedures to refit the turning disc.
Refitting the turning disc
NoteAction
Wipe clean the contact surfaces.1
Rust preventive: 3HAC034903-001
( Mercasol 3110 Waxcoat. Recom-
mended drying time is 24h.)
xx2100002232
Protection type Foundry Plus:
Apply rust preventive to the surface shown in the
figure.
2
Continues on next page
258 Product manual - IRB 5720
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.