Specifications
It is recommended to use multicore cable for the customer connection.
The following describes the cable requirements for the X106 connection in the
extension box.
DescriptionComponent
Flexible oil resistant rubberCable type
4C x 0.5 mm
2
or AWG20Cable area
Included parts
The following parts are included in the delivery when the extension box is selected.
QuantityOrder numberPart
13HAC074661-001Connector for X106
Procedure
Use this procedure to stack an extension box to a basic box.
Info/illustrationAction
Place the controller in desired place.1
Anchor bolts: M8 X 4Fix the basic box to a concrete foundation
or steel platform with anchor bolts.
2
Tighten torque: 11.3 Nm-12.6 Nm
xx1900001450
Remove the four plastic screw.3
Continues on next page
146 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.8.1 Installing the extension box