EasyManuals Logo

ABB OmniCore C90XT User Manual

ABB OmniCore C90XT
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #379 background imageLoading...
Page #379 background image
7.3.2 Troubleshooting the FlexPendant
Description
The FlexPendant communicates with the main computer. The FlexPendant is
physically connected to the panel board. The cable contains the +24 V supply, two
enabling device chains and emergency stop.
Procedure
The procedure below describes what to do if the FlexPendant does not work
correctly.
NoteAction
See Operating manual - Omni-
Core.
Try resetting the FlexPendant using the reset
button located next to the USB port.
1
Note
If protective gloves are used, these
must be compatible with touch-
screens when using the FlexPend-
ant.
If the FlexPendant is not responding or does not
operate correctly, see Problem starting or con-
necting the FlexPendant on page 369.
2
Check the cable for connections and integrity.3
Check the 24 V power supply.4
Read the error event log message and follow any
instructions of references.
5
For more information on the FlexPendant, see Operating manual - OmniCore.
Product manual - OmniCore C90XT 379
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
7 Troubleshooting
7.3.2 Troubleshooting the FlexPendant

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB OmniCore C90XT and is the answer not in the manual?

ABB OmniCore C90XT Specifications

General IconGeneral
BrandABB
ModelOmniCore C90XT
CategoryRobotics
LanguageEnglish

Related product manuals