4.3 Cleaning activities
4.3.1 Cleaning air filter
Location
The air filter is located as shown in the illustration below.
xx1900001473
Required equipment
NoteEquipment
Water 30-40°C with cleansing liquid or detergent.Cleaning agent
Compressed air
Cleaning
The procedure below details how to clean the moist dust filter.
Note/IllustrationAction
How to remove the air filter is detailed
in section Replacing the air filter on
page 284.
Remove the air filter.1
If a fine filter is used, remove the polymeric
filter element first.
2
Clean the filter three or four times.3
Note
Do not wring the filter to press out water.
Allow the filter to dry in one of these ways:
• Lying flat on a flat surface
• Blow with compressed air in opposite
direction of filter airflow.
4
If a fine filter us used, refit a new polymeric
filter element to the filter.
5
Continues on next page
Product manual - OmniCore C90XT 157
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
4 Maintenance
4.3.1 Cleaning air filter