EasyManua.ls Logo

ABB OmniCore C90XT - 4.2 Inspection activities

ABB OmniCore C90XT
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2 Inspection activities
4.2.1 Inspection of controller
Inspecting the OmniCore C90XT controller
Note/illustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx1900001446
Inspect connectors and cabling to make
sure they are securely fastened and
cabling not damaged.
3
Inspect the fans and ventilation holes to
make sure they are clean.
4
After inspection: Temporarily turn the
power supply on. Inspect the fans to
make sure they function correctly. Switch
the power off.
5
156 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
4 Maintenance
4.2.1 Inspection of controller

Table of Contents

Related product manuals