3.4 On-site installation
3.4.1 Required installation space
Dimensions
The following illustration shows the required installation space for the OmniCore
C90XT controller.
355
500
200
500 520
xx1900001448
A free space of 500 mm on the front of the controller is required if the
controller is mounted on a desk (not rack-mounted).
A free space of 200 mm on the back of the controller is required if the
controller is mounted on a desk (not rack-mounted).
A free space of 500 mm on the left side of the controller is required if the
controller is mounted on a desk (not rack-mounted). Do not place any cables
over the left cover as it leads to inefficient cooling.
A free space of 520 mm on the right sides of the controller is required if the
controller is mounted on a desk (not rack-mounted). Do not place any cables
over the right covers as it leads to inefficient cooling.
The following illustration shows the dimensions between the feet of the OmniCore
C90XT controller, as seen from below.