5.3.3 Replacing the fieldbus adapter slave
Location
The illustration shows the location of the fieldbus adapter slave in the controller.
xx1900001474
Required spare parts
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the OmniCore C90XT via myABB Business Portal,
www.abb.com/myABB.
NoteArticle numberSpare part
3HAC062390-001Fieldbus slot cover
DSQC10043HAC045973-001DeviceNet Slave Fieldbus adaptor
[3030-1]
DSQC 6883HAC031670-001ProfiNet Board [3022-1]
DSQC 6693HAC027652-001Ethernet Unit [3025-1]
Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 417.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC065464-009Circuit diagram - OmniCore C90XT
Removing the fieldbus slot cover (baseline)
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Continues on next page
298 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the fieldbus adapter slave