Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx1900001446
Screws: Torx pan head screw M4x8 (2 pcs)Push the power unit until it snaps on the
mounting plate and secure the screws.
3
xx1900001895
xx1900001896
Continues on next page
Product manual - OmniCore C90XT 245
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.9 Replacing the power unit
Continued