Note/IllustrationAction
xx1900001923
Remove the attachment screws on the
door.
5
Push the HMI signal connector into the
cabinet.
6
Take the HMI signal connector out.7
Refitting the HMI signal connector
Refitting the HMI signal connector
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx1900001446
Continues on next page
Product manual - OmniCore C90XT 309
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.3.5 Replacing the HMI signal (FlexPendant) connector
Continued