Specifications
The following describes the cable requirements for the main power connection to
the OmniCore C90XT controller.
DescriptionComponent
Flexible oil resistant rubberCable type
3C x 2.5 mm
2
or AWG14Cable area
Included parts
The following parts are included in the delivery.
QuantityOrder numberPart
13HAC070308-001Power connector
Procedure
Use the following procedure to fit the connectors.
Note/illustrationAction
Cut the cable to desired length.1
xx1900001454
Connect the wires according to the illus-
tration.
2
For single phase:
1 Live (L)
2 Neutral (N)
3 Not used
4 Not used
5 Not used
PE, Protective Earth, grounding
Continues on next page
Product manual - OmniCore C90XT 71
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.5.4 Fitting the connector
Continued