The cable layout is recommended as the following illustration.
xx2000000433
Robot signal exchange proxy mating connectors
xx1900002449
CAUTION
Safety functions must be verified before use. Safety functions must be tested
regularly.
X14
Description
Customer safety interface: emergency stop
and automatic stop
Connection
Weidmüller S2L 3.50 90FType
S2L 3.50/16/90F 3.5SN BK BX 2*8 pins
1728680000 (or equivalent)Article number
Continues on next page
92 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued