BZ001M056A ADT‐DK300A/400A Engraving Machine
92
Range : 0~64
Unit : None
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note : WhileeditingGcodemanually,addalinenumberNxxxxxautomatically
inanewline;
0indicatesthatthisfunctionisdisabled;
048 SystemBaudrate
Range : 9600~115200
Unit : None
Authority : Operationadminorhigher
Default : 115200
Effectivetime : Restart
Note : The communication rate setting when DNC or other PC software and
thiscontrollerareinRS232communicationmode
049 ControlerID
Range : 1~255
Unit : None
Authority : Operationadminorhigher
Default : 1
Effectivetime : Restart
Note : TheIDnumbersettingofthecontrollerwhenDNCorotherPCsoftware
andthiscontrollerareinMODBUScommunicationmode
050
XHomeDir
051
YHomeDir
052
ZHomeDir
053
4HomeDir
Range : 0~1
Unit : None
Authority : Operationadminorhigher
Default : 1,1,0,0
Effectivetime : Instant
Note :
Setthemechanicalhomedirectionofeveryprocessingaxis
Positive