BZ001M056A ADT‐DK300A/400A Engraving Machine
111
050
XEncoderbit(p)
051
YEncoderbit(p)
052
ZEncoderbit(p)
053
4Encoderbit(p)
Range : 0~9999
Unit : Wirenumber
Authority : SuperAdmin
Default : 2500
Effectivetime : Instant
Note : Set the encoderwires connected toevery pulseport (AB phasepulse).
Sincefourtimesfrequencydivisionisperformedforinternaltransfer,the
value of this parameter should be the pulses
collected by the encoder
foronecycledividedby4.
058
XPulseLogicLevel(restart)
059
YPulseLogicLevel(restart)
060
ZPulseLogicLevel(restart)
061
4PulseLogicLevel(restart)
Range : 0~1
Unit : LOGICVOLTAGELEVEL
Authority : SuperAdmin
Default : 0
Effectivetime : Restart
Note : Setthenormalvoltagelevel whenthepulseisworking.Ifthesettingis
different from the normal voltage level required by motor drive, a
directionwillhaveaccumulativeerror
duringeverypositiveandnegative
motion(independentofpulses).Therefore,ifthepositioningaxisofthe
machinehasaccumulativeerrorinadirection,pleasecheckwhetherthis
parametermatches.
062
Xfeature(Rotate0Line1)
063
Yfeature(Rotate0Line1)
064
Zfeature(Rotate0Line1)
065
4feature(Rotate0Line1)
Range : 0~1
Unit : None