BZ001M056A ADT‐DK300A/400A Engraving Machine
115
PrincipalaxisencoderreusesXaxisencoder.
0:Positive
1:Negative
090
XHomeSpeed2
091
YHomeSpeed2
092
ZHomeSpeed2
093
4HomeSpeed2
094
XHomeSpeed3
095
YHomeSpeed3
096
ZHomeSpeed3
097
4HomeSpeed3
Range : 1~20000
Unit : mm/min
Authority : SuperAdmin
Default : 100,60
Effectivetime : Instant
Note : Used to set the speed parameters of mechanical resetting; the specific
eff ectivesequencefollows:
Resetting speed ——> (when detecting external zero switch)
deceleration——>scanningspeed
100 Handwheelencoderdir
Range : 0~1
Unit : None
Authority : SuperAdmin
Default : 0
Effectivetime : Instant
Note : Whenthelogicdirectionobtainedbyhandheldboxencoderisreverseto
the actual motion direction of the axis, set this parameter to perform
in‐phasesetting.
0:positivedirection