BZ001M056A ADTDK300A/400A Engraving Machine
89
031
InpAcceleration(mm/sec)
039
XBacklashExpiate(pulse)
Range : 1~200000,1~200000,1~8000,1~200000
Unit : mm/min,mm/min,mm/sec,mm/min
Authority : Operationadminorhigher
Default : 3000,200,1000,3000
Effectivetime : Instant
Note : ThefeedinginstructionssuchasG01,G02andG03moveatthespeedof
F instruction. If the F instruction isn’t specified in the program, the
above instructions move at
the speed set by this parameter. If the F
instructionisspecified,thisparameterwillbeinvalid.
The maximum feeding speed restricts the F instruction during
processing,i.e. no matter what F is set, the actual speed can’t exceed
this parameter value. Setting this parameter will prevent the damage
caused by accidental speed programming error when transferring
processingfiles.
032
XBacklashExpiate(pulse)
033
YBacklashExpiate(pulse)
034
ZBacklashExpiate(pulse)
035
4BacklashExpiate(pulse)
Range : 1~20000
Unit : Pulse
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
1.Compensatetheclearancebetweencontrolaxis
2. Compensate with the pulse in minimum unit. The specific number
shouldbeconvertedaccordingto gear ratio. Forexample,thebacklash
measured
bythemachinetoolis0.1mmandthegearratioofthesystem
isCMR/CMD=1/1,thecompensationpulsesisp=0.1*1000*1/1=100.
036 ZeroReturnMode
Range : 0~1
Unit : None
Authority : Operationadminorhigher
Default : 0(program)