BZ001M056A ADTDK300A/400A Engraving Machine
90
Note :
0‐Programhome
1‐Mechanicalhome
Progr amhomeisthatthecoordinatesgotohome,i.e.inplace.
Mechanicalhomerequiresexternaldetectionswitchtolocatethehome
position; while home operation, move to specified home direction at
home speed, and move back slowly after signal is detected.
At this
moment,moveforwardslowlywhenthesignalisdisconnected,andthe
home operation completes when the signal is valid again. When the
servoZphaseenable switchin IOconfigurationparameters is enabled,
mechanical home will enable Z phase positioning as home position
automaticallyaftersignalreaches.
037 IOFilterWave(1~8)
Range : 0~8
Unit : None
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
Setthefilterconstant;
If the environment has too much interference, e.g. rain and thunder,
pleaseenter a filter value.Higher value indicates longer test timeand
highreliability;0indicatesnofilter;
038 Communicationmode
Range : 0~3
Unit : None
Authority : Operationadminorhigher
Default : 0
Effectivetime : Restart
Note :
Setthecommunicationmode ofthesystem;
System can communicate through the serial port, network and PC or
other device, 0 is Uart serial port, 1 is network communication, 2 is
NoUserandsystemcommunicationisturnedoff;
040
MaxMPGSpeed(mm/min)

Table of Contents